Warning: If a malfunction exists with related components such as an engine misfire or engine vacuum leak do not perform this test. The oxygen sensor is designed to operate within a particular range, if this range is exceeded the sensor will give the appearance that it has failed.
GM Oxygen Sensor - (appearances will vary)
Oxygen Sensor Test
Tools needed to perform these tests: Voltmeter
- Step 1 - Once the oxygen sensor sensing wire has been located connect a volt meter to the feedback wire and ground. Select the millivolt operation on the meter.
- Step 2 - Next, start and run the engine at idle until warm (about 15 minutes). Observe the voltmeter; it should bounce slightly at whatever voltage the sensor is centered at (about 150 millivolts).
- Step 3 - Continue to observe the meter and have a helper rap the throttle. The meter should drop for a split second as the mixture leans out in the first milliseconds of the throttle bore being opened. Then quickly rise for a spit second as the throttle closes and the mixture richens. The volt meter should stabilize at the original operating voltage when the engine returns to idle
No comments: